Log Placement

Failure to position the parts in accordance with these diagrams or failure to use only parts
WARNING
specifically approved with this heater may result in property damage or personal injury.
CAUTION
periodically afterwards. Set the heater to HIGH and check if yellow
flames come into contact with any log. If so, reposition the logs as
indicated in the below illustrations. Yellow flames coming into
contact with logs create unnecessary soot.
Install the logs exactly as indicated (see Fig. 18 & 19). Do not
modify the logs, and use only logs supplied with the heater. The
logs are numbered and correspond to the numbers listed below.
1.
Place log #1 on pins behind the burner
Place log #2 on pins between burners and
log #3 on pins in front of burner.
Check to ensure that no yellow flame comes in
contact with any log, both after installation and
Fig. 18
After installing the logs, attach screen by hooking the slots on
the ends of the screen on the pins in the side of the fireplace.
Note, logs are not shown for clarity.
2. Place log #4 onto pins in log #1. Place log #5 onto
pins in log #1 and #3. Place log #6 onto pins in logs #2
and #3. Place log #7 onto pins in logs #1 and #2.