OPERATION
DATA CENTER
See Figure 22.
Push the mode button to cycle through the data display
modes.
Voltage: Displays current voltage output.
Frequency (Hz): Displays power output frequency in
Hertz.
Lifetime Hours: Displays the lifetime run hours.
Run Time/Maintenance: Displays current run time.
Resets to zero when shut down. Maintenance reminder
displayed when required.
Maintenance Codes:
P25 - Change engine oil
P50 - Clean air filter, Change engine oil
P100 - Change engine oil, clean air filter, replace
fuel filter
PAIRING THE KEY FOB
See Figures 23 - 24.
l Bring the key fob in range of the generator.
l Ensure the battery is connected and the fuel selector
switch is in the FUEL OFF position .
l Push the battery switch to the ON position.
NOTE: When battery power is available, the battery
indicator light will illuminate and the LED around the
engine start/stop button will illuminate solid green.
l Press and hold the engine start/stop button for 10
seconds until the LED around the button flashes green,
then release it.
l Press and hold the start button on the key fob for one
second, then release it.
• If the key fob paired successfully, the LED around
the engine start/stop button will turn solid green.
• If pairing was unsuccessful, the LED around the en-
gine start/stop button will continue flashing green.
Wait several seconds, then make a second attempt.
If the second attempt fails, turn the battery switch to
the OFF position, wait several seconds and repeat
the process. If subsequent attempts fail, turn the bat-
tery switch to the OFF position and contact customer
service.
l After the key fob is successfully paired to the generator,
turn the battery switch to the OFF position.
BREAK-IN PERIOD
For proper break-in, do not exceed 50% of the rated
running watts during the first five hours of operation.
Use supplied oil until first recommend oil change. Do
not use full synthetic oil during break in period. Full
synthetic oil may prevent proper breaking and seating
of the piston rings.
Vary the load occasionally to allow stator windings to
heat and cool and help seat the piston rings.
24 | English
FIG. 22
A
C
A - Voltage
B - Frequency
C - Lifetime Hours
D - Run Time/Maintenance Reminder
E - Mode Button
FIG. 23
D
A - Red LED
B - Start Button
C - Stop Button
D - Key Fob
FIG. 24
A
A - Fuel Selector Switch
B - Engine Start/Stop Button
C - Battery Indicator
D - Battery Switch
E
B
D
A
B
START
C
STOP
D
B
C