T EC HN I C A L INF O RM AT IO N
Water pressure
Recommended
Maximum
Hot water temp.
Recommended
Maximum
Max. flow rate
@ 44 PSI (0.3 MPa)
* Please know and follow all applicable local plumbing
codes when setting the temperature on the water
heater.
I N STALL ATI ON CO N SI DE R AT I ON S
⁄ For best results, Hansgrohe recommends that
this unit be installed by a licensed, professional
plumber.
⁄ Please read over these instructions thoroughly
before beginning installation. Make sure that you
have all tools and supplies needed to complete
the installation
⁄ This trim is for use with iBox Universal Plus model
01850181 (not included).
⁄ To prevent scald injury, the maximum output
temperature of the shower valve must be no
higher than 120°F (49°C). In Massachusetts, the
maximum output temperature can be no higher
than 112°F (44°C).
2
15 - 75 PSI (0.1 - 0.5 MPa)
145 PSI (1 MPa)
120°-140° F (48° - 60° C)*
158°F (70° C)*
6.8 GPM (25.7 L/min)
E N G L I S H
⁄ This thermostatic mixing valve is for use with a
showerhead rated at 1.1 GPM (4.2 L/min) or
higher.
⁄ If your local plumbing code requires it, install the
throttle to reduce the total flow of water in the
shower to 1.75 GPM (6.6 L/min) @ 80 PSI
(0.55 MPa). See the instructions on page 27.
⁄ When the throttle is installed, this valve cannot be
used as a tub filler.
⁄ Keep this booklet and the receipt (or other proof
of date and place of purchase) for this product in
a safe place. The receipt is required should it be
necessary to request warranty parts.