F. TEMPERATURE MEASUREMENT (see figure 8)
Warning!
To avoid harm to you or damages to the Meter, never attempt to measure voltages
higher than 60V in DC or 30V rms in AC although readings may be obtained.
During testing, the operating temperature must be within 18-23o C, otherwise the
obtained reading may not be correct especially measuring low temperature.
The temperature measurement range is from -40Cº~1000Cº.
To measure temperature, connect the Meter as follows:
1. Insert the "+" and "-" temperature probe into corresponding V
2. Set the rotary switch to ºC.
3. Place the temperature probe's tip to the object being measured.
The measured value shows on the display.
Note:
When there is no temperature probe insert inside the Meter, the LCD displays the Meter
inside temperature.
The included temperature probe can only be measured up to 250ºC. For any
measurement higher than that, the rod type temperature probe must be used instead.
When temperature measeuremnet has been completed, remove the temperature probe away
from the input terminal of the Meter.
(figure 8)
Ω
and COM terminal.