Descargar Imprimir esta página

Simu T5 ZSP Manual Del Usuario página 11

Publicidad

Idiomas disponibles

Idiomas disponibles

RESET THE MOTOR TO FACTORY MODE
13
13.1- Cut the power off for 7 seconds.
13.2- Turn on the power for 7 seconds.
13.3- Cut the power off for 7 seconds.
13.4- Turn the power on.
If the motor is on the end limit position (up or
down), the motor jogs, otherwise, the motor
runs for 5 seconds in random direction.
The motor is now in « Double Power Cute » mode.
If you perform a double power cut to multiple motors, they will all be in this mode. That is why, you
must « cancel » out of this mode on all the motors which you do not want to reset by sending a
command from their individual control transmitter (UP or DOWN).
13.5- Then, confirm the reset of the desired motor from the individual control for that motor:
- Press the « PROG » button of the
transmitter more than 7 seconds.
Maintain the pressure until the
motor jogs twice.
The motor is back in its original factory configuration. No more transmitters are programmed in the memory.
Start programming again from section §4.1.The set functions « Manual lock function », « Obstacle detection »,
« Fabric tension » are kept.
13.1
13.2
ON
7s
1
13.5
PROG >7s
13.4
13.3
ON
7s
7s
5 s
2 s
7 s
US
11/12

Publicidad

loading