3) Remove all ice from the bin.
4) Remove the auxiliary pipe for drain operations near the pump and empty the water tray. Return it to their original
position to avoid water spill.
Pipe for
drain
5) Prepare a solution of an appropriate product for the cleaning of ice machines (lime). Do not use
hydrochloric acid. We recommend the use of any NSF approved scale removal product prepared according to the
manufacturer's instructions.
6) Fill water tray with the solution.
Water tray
7) Switch compressor switch (see figure below) to position 0, and switch on machine in order to run water pump. Let
solution stand for 30-40 minutes and then switch off the machine.
8) Disconnect power and water supplies.
9) Remove the auxiliary pipe to drain and purge out the ice machine scale remover and residue. Replace it.
10) Mix enough cleaning solution (as in point 5) to clean parts and interior food zone surfaces.
Compressor
switch