Descargar Imprimir esta página

Holmes BAP1500 Manual De Instrucciones página 3

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
BAP1500I05M1 v.qxd
2/19/05
10:15 AM
Page 7
U.K. and IRELAND
becomes damaged return to the place of
purchase or phone the helpline number on
the back of this leaflet.
PLEASE READ AND SAVE THESE
• If the supply cord or plug is damaged, it must
IMPORTANT INSTRUCTIONS.
be replaced by the manufacturer or its service
agent or a similarly qualified person in order
With proper care and use, this Bionaire
®
to avoid hazard.
air purifier will give you fresh, clean air
for many years.
• The air purifier contains no user serviceable
parts and should the product suffer damage
NOTE: Before reading these instructions, please
or breakdown it must be returned to the
view the corresponding illustrations.
manufacturer or its service agent.
DESCRIPTIONS (SEE FIG.1)
• Should the air purifier stop working, first check the
fuse in the plug (UK only) or fuse/circuit breaker at
A. Power Light
the distribution board is operating, before
B. Speed Control
contacting the manufacturer or service agent.
C.Oscillation Button
• The ioniser may cause a static charge to build up
D.Ioniser Control
on the air output grill. A static charge may be felt if
E. Filter Indicator Light
the unit is not properly grounded. To avoid a static
charge, plug the unit into a grounded outlet, or
F. Ioniser Light
properly install a ground adaptor. The static shock
G.Washable Foam Pre-filter
will not occur if the ioniser is off.
H.Inlet Grill
• Close supervision is necessary when any
I. PERMAtech™ Filters (2 pcs)
appliance is used by or near children, or
J. Filtered Air Outlet
disabled persons.
SAFETY PRECAUTION
HOW THE AIR PURIFIER WORKS
Carefully read and retain all instructions before
Dirty, dust laden air is drawn through the back of
using the air purifier.
the air purifier and through the multi-stage
• To avoid fire or shock hazard, check that the
filtration system.
voltage on the product corresponds to your
1. The carbon filter will help clear odours making
electricity supply and plug directly into an
the air cleaner and fresher.
electrical outlet.
2. The PERMAtech™ filter entraps 99% of all
• Keep cord out of heavy traffic areas and to
smaller visible and non-visible particles down
avoid fire hazard, never put the cord under
to 2 microns in size.
rugs, or near any heat source.
IONISER
• Carefully discard any plastic wrapping that
was used for the packaging. If the filter is
Your Bionaire
covered by a bag when shipped, remove
controlled ioniser, which when turned on,
plastic bag before use.
releases negative ions into the outgoing filtered
• Do not use the air purifier outside.
air. Ions are tiny particles that carry either a
• Do not place the unit near any heat source or
positive or negative charge. These ions exist
in direct sunlight.
naturally all around us in the air, water and
• Always unplug the air purifier before moving it,
ground. Both positive and negative ions are
opening the grill, changing the filters, cleaning
colourless, odourless and completely harmless.
the air purifier or whenever it is not in use.
Negative ions help the air purification process
• Do not use in or around water or any other
by attaching themselves to very small airborne
liquids. Do not attempt to wash the unit under
particles in the room. These particles take on a
running water.
negative charge and may join with positively
• Use appliance only for intended household
charged particles, such as dust, pollen, smoke
use as described in this manual.
and pet dander to form larger particles that are
• Ensure that all air openings are not restricted
then more readily captured by the filter system,
or covered in any way.
or they may be attracted to positively charged
surfaces like walls or floors.
• Do not place anything on top of the unit.
You may also note, after extended use, that dust
• Never insert any object into any openings.
may have collected around the grills or front panel.
• Do not use the air purifier if any part is
This is from the ionisation effect caused by the
missing or damaged in any way.
negative ions exiting from the air outlet.This dust
• Do not attempt to repair or adjust any
does not come from the air output, but Is drawn out
mechanical functions of this unit. If the unit
2
of the uncleaned air going past the air outlet.
This is additional evidence of the air cleaning
effectiveness of negative ions. The dust can be easily
removed with a clean, dampened cloth or soft brush.
NOTE: it is important to clean the PERMAtech™
filters at recommended intervals. Using the ioniser
in conjunction with dirty filters may result in dirty
particles exiting the air purifier and being attracted
to walls, carpets, furniture and other household
objects. These dirty particles may prove very
difficult to remove.
PRE-OPERATING INSTRUCTIONS
1. After removing the unit from the box, remove
the plastic covering from the unit.
2. Select a firm level place where there are no
obstructions to the air inlet (rear grill) or
filtered air outlet.
3. Remove the inlet grill by pulling the grill
towards you.
4. Remove both PERMAtech™ filters by gripping
on both sides and pulling forward.
5. Remove protective plastic bag from each filter
cartridge. The filter clip can only be attached
to the hang tabs on the filter one way (see
Fig. 2). The filter clip should easily slide onto
the filter hang tabs. Do not use force whilst
attaching the filter clip to the filter. Align the
clip on the PERMAtech™ filter with the rails
on the inside of the unit.(see Fig. 3)
NOTE: The pleated material and rubber gasket
should be facing towards the unit when applied.
6. Replace the inlet grill by sliding back on to the
unit. Make sure that it snaps securely into
position (the grill only goes on one way).
NOTE: Do not point outlet towards wall.
®
Air Purifier has an independently
OPERATING INSTRUCTIONS
Your remote control requires (2) AAA batteries
(not included) for operation. Remove batteries
before discarding the remote control. To install
the batteries, simply depress and slide the back
of the remote control with your thumb on the
arrow indentation. Insert batteries according to
the diagram shown inside and replace cover.
• DO NOT mix old and new batteries.
• DO NOT mix alkaline, standard (carbon-zinc)
or rechargeable (nickel-cadmium) batteries.
1. Plug into a suitable electrical outlet.
2. Press the power button (
panel or the remote control. The unit will turn on
high only the first time the unit is turned on. All
other times it is turned on, the unit remembers
the last speed selected and will turn on at that
speed and the power light will illuminate letting
you know the power is on.
3. You can then select the desired speed
setting. This air cleaner has three speed
settings. You can select from HIGH (
),
MEDIUM(
), or LOW (
) by pushing the
desired operating speed button on the control
panel or the remote control.
4. To release negative ions into the filtered air,
press the ioniser button (
) either on the
control panel or the remote control and the
light will illuminate.
5. The ioniser will not work unless the unit is
running.
6. For optimum air filtration, it is recommended to
operate the air purifier continuously. Its rugged
motor is designed to give many years of service.
7. For continuous use it is recommended to operate
the air purifier at the Medium (
) setting. For
quieter operation or use in a bedroom, select the
Low (
) setting. When high levels of air pollution
are present, select the HI (
) setting to quickly
circulate clean filtered air.
8. The air purifier is equipped with oscillation. To
start and stop oscillation of the air cleaner,
push the button identified as Oscillation (
on the remote control or control panel.
CLEANING AND MAINTENANCE
1. Turn the air purifier off and unplug it before
cleaning.
2. The outside of the air purifier can be cleaned
with a soft, clean dampened cloth.
3. The rear air inlet grill can be removed and
washed in warm soapy water (not dishwasher
safe). Dry before replacing in the unit.
4. The filtered air outlet can be cleaned of dust
with a small, soft brush.
5. If you wish to clean the inside of the air purifier,
please only use a dry, soft cloth to wipe it down.
PERMATECH
FILTER CLEANING
TM
Filter Indicator Light (E) - Your air purifier has an
indicator light that illuminates when it is time to
clean the PERMAtech™ filters.
1. Every few weeks check the condition of the
pre-filter.
2. Remove the inlet grill. If the foam pre-filter has
collected a noticeable amount of dust, remove it
from the inlet of the grill and wash it in warm soapy
water. Rinse and dry the pre-filter thoroughly
before replacing it in the inlet of the grill.
3. With the inlet grill removed, check the
) on the control
condition of your PERMAtech™ filters. If the
filters are dirty, remove them by gripping on
both sides and pulling forward.
4. To clean the PERMAtech™ filter use a crevice
tool or brush attachment with your vacuum
cleaner. Run the attachment along the inlet and
outlet side of the filter trying to clean between the
pleated filter layers. (see Fig. 4).
3
)

Publicidad

loading