Descargar Imprimir esta página

Lenze L-force 9400 E94AYAE-SM301 Instrucciones Para El Montaje página 19

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Displays
All manuals and user guides at all-guides.com
Pos.
Colour
MS
Green
(Module State)
EN
Yellow
(Enable)
ME
Red
(Module Error)
AS
Yellow
(Acknowledge
Stop)
BE
Red
(Bus Error)
DE
Red
(Drive Error)
Blinking: on/off every 0.5 s
EDK94AYAE DE/EN/FR/ES/IT 1.1
State
Description
On
Drive-based safety is initialised faultlessly.
Drive-based safety is initialised faultlessly. Internal
Blinking
communication to the basic device is not possible.
Drive-based safety is in service status.
Flashing
For exiting, parameterise the drive-based safety.
Drive-based safety is not initialised.
Off
Acknowledgement is not possible.
On
Controller enabled
Off
Non-safe display "STO"
On
System error
Blinking
Trouble
Flashing
Warning
Off
Error-free operation
Request of an acknowledgement for the restart or the
On
parameter set adoption
Blinking
SS1/STO active
Flashing
SS2/SOS active
Off
No stop function active
Safety bus error:
On
Communication is not possible.
Acknowledgement is possible.
Blinking
Safety bus error: no valid configuration.
Off
Safety bus: error-free operation.
Drive-based safety is not accepted by the basic device
On
(see notes in the instructions for the basic device).
Drive-based safety is correctly recognised by the basic
Off
device.
Flashing: on/off every 0.1/0.9 s
19