Problem
Unit not working.
Not enough humidity
Fan not operating
Fan running continuously
Water leaks out of back of unit.
Poor evaporation of water.
CALL 1.800.547.3888 OR VISIT AIRCAREPRODUCTS.COM
TROUBLE SHOOTING
Probable Cause
• No power supplied to outlet.
• The On/Fan knob is not in the On
position.
• Humidity level is not set high
enough
• Reservoir is empty
• Dirty wick
• Ambient humidity level is not
3% or more below selected the
humidity level.
• Reservoir is empty.
• Float retainer is in dryout posi-
tion (see page 8)
• Humidity level is set to highest
position.
• Humidity level has not reached
the desired level yet.
• Water splashing during filling.
• Too much water added
• Check Filter message (CF)
message flashing
• Mineral buildup on filter (wick)
11
Remedy
• Check 120 volt power source
• Turn the left hand knob clockwise and note the
POWER indicator light come on.
• Turn humidity level up
• Increase fan speed
• Fill humidifier with water
• Replace wick
• Raise the selected humidity level if desired
• Refill the humidifier with water
• Reposition float to the normal operating position
• Setting the humidity to highest setting (65%)
causes the fan to run continuously. Adjust to a
level between 25% and 60%.
• Continue to run until desired humidity level is
achieved. This may take up to 48 hours initially
• DO NOT OVERFILL the reservoir. Note the "Full"
label in cabinet.
• Deflect fill water off the center of the splash guard
• Change to a new wick
NOTE: Local water varies from area to area and
under certain conditions minerals will build up more
rapidly in the wick
• Unplug unit for 1-2 minutes to reset CF function