function
Dc Voltage
ac Voltage
Dc current
resistance
Battery test
• Diode test: Approx. 1mA, open circuit voltage 2.0V DC
• continuity check: Audible signal <100Ω
• Battery test: 9V (6mA); 1.5V (100mA)
• Sampling frequency: 2 samples per second
• overload: "OL" indicated on display, overload protection
• polarity: "-" on display indicates negative polarity
• Display: 3 ½ digit, 2000 Count LCD
MM300-1390109ART.indd 3
electrical SpecificationS
range
200.0mV
2000mV
20.00V
(V Dc)
200.0V
600V
200.0V
(V ac)
600V
200.0μA
20.00mA
(a Dc)
200.0mA
10.00A
200.0Ω
2000Ω
20.00kΩ
200.0kΩ
2000kΩ
9V
1.5V
600V RMS in all settings
Dwg Name: MM300-1390109ART
Dwg No: 1390109
ECO No: 20617
Pkg Dwg Ref: 1290186
Color Reference: N/A
resolution
0.1mV
1mV
±(0.5% + 3 digits)
0.01V
0.1V
±(0.8% + 3 digits)
1V
0.1V
±(1.2% + 10 digits)
1V
0.1μA
±(1.0% + 5 digits)
10μA
100μA
±(1.2% + 5 digits)
10mA
±(3.0% + 5 digits)
0.1Ω
±(1.0% + 5 digits)
0.01kΩ
0.1kΩ
1kΩ
±(1.5% + 5 digits)
10mV
±(1.0% + 2 digits)
10mV
±(1.0% + 2 digits)
Rev: E
accuracy
50 to 60Hz
3
9/21/2015 2:48:00 PM