3
LUBRICATION
3.1
Recommended lubricants
We recommend using a synthetic PAO based oil with viscosity 150 Cst at 40°C to lubricate the DRP+
such as one of the followings (or an equivalent); for alternates, please consult us.
Trade mark
KLUBER
MOBIL
TOTAL
SHELL
LUBCON
3.2
Oil filling: right-angle configuration (DRP+R & DRP+P)
DRP+ are delivered with sight glasses and breathers in a separate plastic bag. They must be installed in
the correct position described in the following procedure and sketches.
1. Place the sight glass in the correct position.
2. Remove the two input plugs of the DRP+R & DRP+P (on the upper face of the bevel box).
3. Fill the DRP+R & DRP+P slowly until the oil level reaches the middle of the sight glasses. Note that
the level on the sight glass may take some time to stabilize.
4. Re-install the oil input plugs.
5. Install the 2 breathers (one per circuit) on the upper face of the bevel boxes in the place of the red
original plugs. (Except external forced lubrication).
6. Run the unit until it reaches operating temperature. Stop the unit, check and adjust the level.
Note:
For DRP1+R & DRP1+P the breathers are not necessary.
WARNING!
The DRP+ is delivered WITHOUT oil and has 2 independent lubrication circuits. Fill them
with oil before using the DRP+.
Any damage due to incorrect lubrication will void the warranty.
WARNING!
The rack and the output gears must be lubricated before running the DRP+.
KLUBERSYNTH EG4-150
MOBILGEAR SHC XMP 150 or
MOBIL SHC629 (warning: life time 7500 hours)
CARTER SH150
TURMOSYNTHOIL 150
WARNING!
An O-ring seal insures the leak tightness of the oil plugs. Tighten carefully the plugs in
order to avoid damaging the seal.
This document must not be reproduced nor information therein disclosed without our authorization
DRP+ User manual
Oil reference
OMALA HD150
Ref.: RX182/009
Version 01/2017 - English
Page 4 / 30