6 Commissioning
6 Commissioning
DANGER
Risk of injury
The following instructions must be followed during all maintenance, servicing, assembly, disassembly, and repair work:
• Close the gas supply.
• Disconnect all electrical connections.
• Switch off the pressure and bleed the lines.
NOTICE
• Note the following instructions:
3 Product description on page EN-4
• The system may be installed and commissioned only by qualified personnel (in Germany, see TRBS 1203).
6.1 Mounting the device
NOTICE
• Mount the device in the front of the solenoid valve (as close to it as possible) in the wire feeder and in the direction
of gas.
• Remove any additional gas management systems within the gas line. They impact the device.
Fig. 1 Functional description on page EN-7
1 Insert the mounting screws (not included in scope of supply) in the slots (5) to mount the device with the correct mounting
orientation (connectors face down).
6.2 Interfaces
The following interfaces are used by both device versions for communication purposes:
Interfaces
Touch buttons
Jack interface
CANopen
Ethernet
Tab. 9
Interfaces
6.3 LED status display
The LED status display indicates the following:
LED color
Green
Red
Alternating green +
orange flashing
Alternating red +
orange flashing
Continuous orange
Tab. 10
LED status display
EN - 8
EWR 2
Test, diagnosis, and configuration of device
–
–
Meaning
Device switched on = regulation of shielding gas flow
Device switched off ("bypass" appears on the display) = no regulation of shielding gas flow
Device switched on and error message/malfunction appears
Device switched off and error message/malfunction appears
Device not ready for use = erroneous calibration data Have the device recalibrated by
an ABICOR BINZEL service technician
EWR 2 Net
For operating the device
Set point input for gas flow,
process data recording
Set point input for gas flow, process data
recording, configuration of device
EWR 2 / EWR 2 Net
BAL.0598 • 2018-04-09