EWR 2 / EWR 2 Net
11 Disassembly
DANGER
Risk of injury due to unexpected start
The following instructions must be followed during all maintenance, servicing, assembly, disassembly, and repair work:
• Close the gas supply.
• Disconnect all electrical connections.
• Switch off the entire welding system.
NOTICE
• Disassembly must only be carried out by qualified personnel (in Germany, see TRBS 1203).
• Observe the information provided in the following section:
8 Decommissioning on page EN-16.
1 Close the gas supply.
2 Switch off the power supply.
3 Switch off the entire welding system.
4 Remove the connection cables from the power supply (24 V).
5 Remove the shunt and the connecting cable.
6 Remove the insulating gas hose from the gas supply line and the gas discharge line.
12 Disposal
When disposing of the system, local regulations, laws, provisions, standards and guidelines must be observed. To correctly
dispose of the product, it must first be disassembled.
11 Disassembly on page EN-19
12.1 Materials
The product housing is made of aluminum. Furthermore, the electronic components must be sent for recycling as electronic
scrap. The plastic materials used are labeled in preparation for their sorting and separation for later recycling.
12.2 Consumables
Oil, greases and cleaning agents may not contaminate the ground or enter the sewage system. These substances must be
stored, transported and disposed of in suitable containers. Observe the relevant local regulations and disposal instructions
in the safety data sheets specified by the manufacturer of the consumables. Contaminated cleaning tools (brushes, rags, etc.)
must also be disposed of in accordance with the information provided by the consumables' manufacturer.
12.3 Packaging
ABICOR BINZEL has reduced the transport packaging to the necessary minimum. The ability to recycle packaging
materials is always considered during their selection.
13 Appendix
13.1 Setting the serial communication
• Baud rate (speed)
• Data bits
• Stop bits
• Parity
Tab. 31
Setting the serial communication
BAL.0598 • 2018-04-09
115200 baud
8
1
None
11 Disassembly