EWR 2 / EWR 2 Net
9 Service and cleaning/repair and recalibration
Scheduled maintenance and cleaning are prerequisites for a long service life and trouble-free operation.
DANGER
Risk of injury
The following instructions must be followed during all maintenance, servicing, assembly, disassembly, and repair work:
• Close the gas supply.
• Disconnect all electrical connections.
• Switch off the entire automated system, if necessary.
DANGER
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed, or worn parts.
NOTICE
• The specified maintenance intervals are standard values and refer to single-shift operation.
• Maintenance and cleaning work must only be carried out by qualified personnel (in Germany, see TRBS 1203).
• Always wear your personal protective equipment when performing maintenance and cleaning work.
9.1 Monthly maintenance and cleaning
• If necessary, clean the device with a dry cloth.
• Check the device, power supply, shunt and gas hoses daily for damage and replace them, if necessary.
9.2 Repair and recalibration
Devices may be repaired and recalibrated only by ABICOR BINZEL service personnel. We recommend you recalibrate
the device every 24 months upon commissioning.
Contact details for consultation and placing orders can be found online at www.binzel-abicor.com.
10 Troubleshooting
DANGER
Risk of injury and device damage when handled by unauthorized persons
Improper repair work and modifications to the product may lead to serious injuries and damage to the device. The
product warranty will be rendered invalid if work is carried out on the product by unauthorized persons.
• Operating, maintenance, cleaning and repair work may be carried out only by qualified personnel (in Germany,
see TRBS 1203).
Note the attached document regarding the warranty. In the event of questions and/or problems, contact your retailer or the
manufacturer.
NOTICE
• Please also consult the operating instructions for the welding components, such as power source and welding
torch system.
BAL.0598 • 2018-04-09
9 Service and cleaning/repair and recalibration