3.3
ACCESS TO
INSTALLER'S
5
PARAMETERS
For.access.to.the.installer's.parameters,.
press. simultaneously. the.
3
.or.2.seconds.(3.fig..12)...
For. example,. the. parameter. PAR. 23. is.
1
visualised. on. the. display. of. the. control.
panel.in.the.following.way:
2
4
5
5
The. parameters. scroll. forwards. and.
.e.1.850.rpm)
backwards.with.the.key.
the. default. parameters. can. be. changed.
with.the.keys.
. and.
The.standard.visualisation.returns.auto-
1
1
matically. after. 60. seconds,. or. by. pres-
sing. one. of. the. control. keys. (2. fig.. 12).
es..14.000.e.10)
excluded.the.key.RESET.
2
2
3.3.1
Replacing the board or
RESETTING parameters
..97.000.e.500)
If. the. electronic. board. is. replaced. or.
reset,.it.is.necessary.to.configure.PAR.1.
and. PAR. 2. by. associating. the. following.
values.to.each.type.of.boiler.to.be.able.to.
restart.the.boiler:.
GAS
.
.
.
.
.
METHANE.
.
(G.20).
.
.
.
.
.
.
.
.
.
.
. .PROPANE.
.
(G.31).
.
.
5
FAST CONFIGURATION
PAR. DESCRIPTION...
.
3
.1.
keys.
. and.
.
.2.
1
.
.3.
..
.
2
.4.
.
.
4
.
5
5
.
.5.
.
.
3
3
.
.and.
and.
.
3
3
1
1
.
..
.6.
.
.7.
..
2
2
.
.8.
4
4
.
.9.
.10.
4
4
..
.
.
.
.11. Correction.values.external.sensor.
.12.
..
..
.13.
..
MODEL
PAR 1
..
.
.14.
220.BOX.
.
330.BOX.
8
.15.
440.BOX.
.
550.BOX.
.
.16.
.
.
.
.17. ModBus.communication.configuration...1.....30..
.19. Type.circuit..
220.BOX
.
330.BOX.
16
D.H.W. - HEATING
440.BOX.
PAR. DESCRIPTION...
550.BOX
.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
.
38.
39.
.
PARAMETERS INSTALLER
RANGE.
.
.
Combustion.configuration.
--.=.ND.
.
1.....31.
Hydraulic.configuration.
--.=.ND.
.
1.....14
Timetable.2.programmer.
1.=.DHW.+.Recirc..pump.
.
2.=.DHW.
.
3.=.Recirculation.pump
Pressure.transducer.disabler.
0.=.Disabled.
.
1.=.Enabled.0-4.BAR
.
2.=.Enabled.0-6.BAR
.
3.=.Enabled.0-4.BAR.(NO.ALL.09)
.
4.=.Enabled.0-6.BAR.(NO.ALL.09)
Assignment.of.auxiliary.relay.AUX.. 1.=.Remote.supply.
.
2.=.Recirculation.pump
.
3.=.Automatic.load.
.
4.=.Remote.alarm.NC
.
5.=.Heat.pump
.
6.=.Zone.2.valve.
Luminous.bar.indicating.presence. 0.=.Disabled.
of.voltage.
1.=.Enabled
Allocation.of.CR73.channels...
0.=.Not.assigned.
.
1.=.Circuit.1.
.
2.=.Three-zone.circuit
Fan.rpm.Step.ignition.
0,0.....81.
.
.
Long.chimneys.
0.....20.
Remote.control.option.setting..
1.=.CR.73.
.
2.=.CR.53.
.
3.=.RVS.43.143
.
4.=.RVS.46.530
.
5.=.RVS.61.843
-5.....+5.
Backlighting.duration.
--..=.Always.
.
0.=.Never.
.
1.....199.
Modulating.pump.speed.
--.=.None.
.
AU.=.Automatic.mod..
.
30...100.=..%.Settable..
.
..................modulation
Setting.second.input.TA..
--.=.Contact.TA.
.
5...160.=.Input.0...10VDC
Cascade.address..
--.=.Not.enabled..
.
0.=.Master
.
1...7.=.Slaves
ModBus.address..
--.=.Not.enabled..
.
1...31.=.Slaves
0.=.Two.zones..
.
1.=.Three.zones
RANGE.
.
.
Minimum.heating.temperature.Zone.1... PAR.64.OEM.....PAR.21.
Maximum.heating.temperature.Zone.1... PAR.20.....PAR.65.OEM.
Heating.curve.slope.Zone.1...
3.....40.
Minimum.heating.temperature.Zone.2... PAR.64.OEM.....PAR.24.
Maximum.heating.temperature.Zone.2... PAR.23.....PAR.65.OEM.
Heating.curve.slope.Zone.2...
3.....40.
Minimum.heating.temperature.Zone.3... PAR.64.OEM.....PAR.27.
Maximum.heating.temperature.Zone.3... PAR.26.....PAR.65.OEM.
Heating.curve.slope.Zone.3...
3.....40.
∆t.heating.circuit.
10.....40.
Post-circulation.heating.time...
0.....199.
Maximum.heating.capacity...
30.....100.
Zone.1.pump.activation.delay...
0.....199.
Start-up.delay...
0.....10.
Additional.source.activation.threshold... --.,.-10.....40.
Boiler.antifreeze...
0.....+20.
External.sensor.antifreeze...
-5.....+5.
--..=. Disabled .
Band.saturation....
flowmeter.modulation...
0.....100.
D.H.W..post-circulation.time..
0.....199.
0.=. Disabled .
Anti-legionella..
(only.D.H.W.tank)).
1.=. Enabled
UNIT.OF.
INC/DEC..
DEFAULT
MEASUREMENT. UNIT.
SETTING
=.
=.
"-.-"
.
.
=.
=.
"-.-"
=.
=.
1
=.
=.
1
=.
=.
1
=.
=.
1
=.
=.
1
rpmx100. 0,1 from.0,1.to.19,9.
0,0
.
1 from.20.to.81
%.
1.
0
=.
=.
1
°C.
1.
0
sec..x.10.
1.
3
%.
10.
--
--.
--.
--
--.
1.
--
--.
1.
--
--.
1.
25
--.
--.
0
UNIT.OF.
INC/DEC..
DEFAULT
MEASUREMENT. UNIT.
SETTING
°C.
1.
20
°C.
1.
80
--.
1.
20
°C.
1.
20
°C.
1.
80
--.
1.
20
°C.
1.
20
°C.
1.
80
--.
1.
20
°C.
1.
20
Sec..
10.
30
%.
1.
100
10.sec..
1.
1
Min..
1.
3
°C.
1.
"-.-"
°C.
1.
3
°C.
1.
-2
%.
1.
100
Sec..
1.
0
--.
--.
0
ES
ENG
59