H Pistas de auditoría metrológicas en iGEM de EE.UU.
MEASURE/METER TYPE
This log tracks the unit of measure as well as the type of meter for which the iGEM is configured. The event coun-
ter has a capacity of 1000 (1-1000). Details of the last 10 changes are logged.
176
CLEAR
"1" Meter Type = 1 (iMeter)
"US Gal" = US Gallons
"UC 1" = Unit of measure change record 1
"UC 3-9" = Unit of measure change records #3-#9
CLEAR
"7.01" = 7 total changes,
meter type = 1 (iMeter)
"US GAL" = Currently set to US Gallons
"Unit" = Unit of measure change record 1
toggle
toggle
WU017834
"9.30.09" = Date of change
"09.04" = Time of Change
"bC 1" blend ratio change record 1
"nonE" = No Changes
"UC 10" = Unit of measure change record 10
Rev 02
06/2020