Metabo HPT NR 38AK Instrucciones Y Manual De Seguridad página 13

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Push Lever Nose
This tool is equipped with a lockout feature that prevents
the tool from being activated when there are 4 or less nails
in the magazine.
Before actually beginning the nailing work, test the Nailer
by using the checklist below. Conduct the tests in the
following order.
If abnormal operation occurs, stop using the Nailer
and contact a metabo HPT authorized service center
immediately.
(1) DISCONNECT AIR HOSE FROM NAILER.
REMOVE ALL NAILS FROM NAILER.
□ ALL SCREWS MUST BE TIGHTENED.
If any screws are loose, tighten them.
□ THE PUSH LEVER AND TRIGGER MUST MOVE
SMOOTHLY WITH PULLING BACK THE NAIL
FEEDER.
Push Lever
(2) Adjust the air pressure to 70 psi (4.9 bar 5 kgf/cm
Connect the air hose.
Do not load any nails in the Nailer.
□ THE NAILER MUST NOT LEAK AIR.
At Firing
Push
Lever
Nose
Workpiece
Do not connect
air hose
Nail Feeder
Hold the Nailer downward and pull the trigger with
pulling back the nail feeder.
□ THE NAILER MUST NOT DRIVE.
Pull Trigger
(3) With fi nger off the trigger, depress the push lever
against the workpiece.
□ THE NAILER MUST NOT DRIVE.
(4) Without touching the trigger, fi rst depress the push
lever against the workpiece.
Pull the trigger with pulling back the nail feeder.
□ THE NAILER MUST DRIVE.
).
2
English
Nail Feeder
Do not pull Trigger
Depress Push Lever
13

Publicidad

Tabla de contenido
loading

Tabla de contenido