Attention! The fitting must be installed, flushed and
tested after the valid norms.
Assembly
1. Flush through the supply pipes.
2. Place the mixer including the sealing washer in
position on the basin / bidet.
3. Slide the fixation piece including the washer
over the threaded pins and tighten the nuts.
4. Connect the supply pipes to the isolation valves;
cold right - hot left.
5. Connect the pull rod to the pop-up waste.
The hot and cold supplies must be of equal
pressures.
Technical Data
This mixer series-produced with waterdim-
mer (flow limiter)
Rate of flow with waterdimmer:
Rate of flow without waterdimmer:
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Hansgrohe single lever mixers can be used toge-
ther with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 0.15 MPa.
If the continuous water heater causes any problems or
there is not enough flow of water, the waterdimmer®
(6a) located behind the aerator must be removed.
To adjust the hot water limiter on single lever mixers,
please see page 15.
No adjustment is necessary when using a continuous
flow water heater.
English
Spare parts (see page 3)
1
1.1 screw cover
2
3
4
5
6
7
8
9
10 pull rod
11 locking screw for handle
12 spout cpl.
13 sealing set
Special accessories
X
7 l/min 0.3 MPa
14l/min 0.3 MPa
max. 1 MPa
0.1 - 0.5 MPa
1,6 MPa
max. 80° C
65° C
handle
flange
nut
cartridge cpl.
seal
aerator cpl.
fixing set
connection hose 450 mm
connection hose 450 mm
special tool set
(order as an extra)
32095000
96338000
96763000
97209000
92730000
95008000
94010000
13961000
94071000
97372000
96657000
96059000
96521000
92646000
58085000