Suction turbine does not run
Reset the suction turbine fuse on the
control panel.
Insufficient vacuum performance
Clean the vacuum bar.
Check, clean or replace the seal on the
dome.
Empty the waste water tank.
Insert the suction hose properly on the
dome.
Check the suction hose for damages.
No water exiting from nozzle
Set the appliance switch to normal op-
eration.
Fill the fresh water tank with hot water
(max. 60°C) and rinse the nozzle. Re-
place the nozzle as applicable (see
"Maintenance task/replace nozzle").
Fill up fresh water reservoir.
Clean the sieve in the fresh water reser-
voir.
Brush does not turn
Set the appliance switch to normal op-
eration.
Reset the brush drive fuse on the con-
trol panel.
Check the drive belt, replace if required.
Carpet gets too wet
Replace the worn nozzle with a new
one (see "Maintenance task/replace
nozzle").
Technical specifications
Power
Nominal voltage
Type of protection
Average power con-
sumption
Suction engine output W
Brush engine output
Cleaning brushes
Working width
Brush diameter
Brush speed
Detergent pump pres-
sure
Detergent pump flow
rate
Max. water tempera-
ture
Vacuuming
Cleaning power, air
quantity
Cleaning power, nega-
tive pressure
Dimensions and weights
Theoretical surface
cleaning performance
Fresh/waste water
tank volume
Length
Width
Height
Typical operating
weight
Noise emission
Sound pressure level
(EN 60704-1)
Machine vibrations
Vibration total value
(ISO 5349)
– 6
EN
V/Hz
220...240/
1~50/60
IPX4
W
1300
1130
W
76
mm
260
mm
65
1/min 1650
MPa
0,4
I/min
1,4
°C
60
l/s
46
kPa
30,2
m²/h
100
l
15/17
mm
920
mm
360
mm
750
kg
52
dB(A) 77
m/s²
1,7
15