WARNING when using R32/R290 refrigerant
Do not use any means other than those recommended by the manufacturer to speed up the defrosting
process or clean the device.
The device must be stored in a room without continuously operated sources of ignition (e.B. open
flames, an operating gas device or an electric heating system).
Do not pierce the refrigeration circuit or work with an open flame without appropriate preparations.
Note that the refrigerant may be odourless.
The device should be installed, operated and stored in a room with a floor area equal to the amount
of refrigerant to be filled in (see table). Please refer to the appropriate label on the device itself for
specific information on the type of gas and the quantity. In the event of a difference between the
information on the label and the operating instructions for the min. room area (m2), the description on
the label shall take precedence.
Amount of refrigerant (kg)
Compliance with national gas regulations must be observed.
Keep the ventilation openings free of obstacles.
The device should be stored in such a way that no mechanical damage occurs.
The device should be stored in a well-ventilated location where the room size corresponds to the
room area specified for operation .
Any person working on or opening a refrigerant circuit should have a valid certificate from an
accredited assessment authority authorising their expertise in the safe handling of refrigerants in
accordance with a recognised assessment specification. Maintenance may only be carried out on
the instructions of the device manufacturer. Maintenance and repair work requiring the support of
other professionals must be carried out under the supervision of the person responsible for the use
of combustible refrigerant.
The device should be stored in a room where no open flames (e.B. a gas device) and no ignition
sources (e.B. an electric operating heater) are in continuous operation.
Warning: Fire
hazard/combustible
materials
page
6
Min. space (m²)
Amount of refrigerant (kg)
5
6
7
8
9
10
Explanation of the symbols displayed on the device
(only the refrigerant R32/R290 is used for the device):
This symbol indicates that this device uses a combustible
Warning
refrigerant. If the refrigerant leaks and is exposed to an
external ignition source, there is a risk of fire.
This symbol indicates that the user manual must be read
Attention
carefully.
This symbol indicates that service personnel should
Attention
operate this device in accordance with the user
manual.
This icon indicates that information such as the
Attention
operation or assembly instructions are available.
Min. space (m²)
11
11
12
13
14
15