WIRING
W A R N I N G
s
WARNING
!
building codes before installation. The installation must be in
accordance with their regulations as well as the most recent
National Electrical Code (NEC).
Check the pump label for proper voltage required. Do not connect
to voltage other than that shown.
A ground fault circuit interrupter (GFCI) is required.
s
WARNING
!
mounted to the pump must not be modified in any way, with the
exception of shortening the cord to fit into a control panel. Any splice
between the pump and the control panel must be made within a
junction box mounted outside of the basin and comply with
the National Electrical Code. Employ a licensed electrician.
s
WARNING
!
Do not use the power cord for lifting the pump.
SPECIFICATIONS
Discharge Size
1-1/4" FNPT with 3/4" garden hose adapter
Intake
Pump Housing
Epoxy-coated cast aluminum
Volute
Impeller
Single-phase permanent split capacitor with
Motor
automatic reset thermal overload protection
Pump Shaft Seal
Power Cord
18 AWG 3-conductor, copper, stranded, 10' length
These pumps are capable of operating with the motor
housing partially exposed for extended periods, providing
sufficient motor cooling and bearing lubrication. However,
Cooling
for the best cooling and longest motor life, the liquid
level being pumped should normally be above the
top of the motor housing.
All manuals and user guides at all-guides.com
W A R N I N G
Check local electrical and
The flexible jacketed cord assembly
Screened bottom
Aluminum
Plastic
Lip
MAINTENANCE
W A R N I N G
s
CAUTION
!
Before working on the pump, always
unplug the pump power cord in addition to removing the fuse or
shutting off the circuit breaker.
This unit is permanently lubricated. Oiling is not required.
Do not, in any case, open the sealed portion of the unit
or remove housing screws.
1.
The motor housing of the pump is completely sealed and
requires no service.
s
NOTICE
!
Disassembly of the motor housing or
alteration of the power cord voids all warranty.
2. LET PUMP COOL FOR A MINIMUM OF 2 HOURS BEFORE
ATTEMPTING TO SERVICE.
3. Check the power cords and electrical outlet for
damage or corrosion.
a. The power cord on these units cannot be replaced.
In case of damage, the whole unit must be replaced.
4. Periodic cleaning of the pump parts will prolong the life and
efficiency of the pump. Remove the four screws holding the
base to the motor housing and clean the impeller. Do not use
strong solvents.
s
CAUTION
!
a.
Removal of the impeller requires special tools and is to be
done only by an authorized service center.
b. Be sure the impeller turns freely after cleaning.
c. Attach the base to the motor housing and secure it
with the four screws.
W A R N I N G
Do not remove the impeller.
5