4.2
Laser distance measurement
Wavelength
Laser color
Laser class in accordance with IEC 60825-1
Maximum average power output
Pulse duration
Pulse frequency
Beam divergence
4.3
Angle measuring precision (ISO 17123-3)
PLT 400­2
PLT 400­4
4.4
Distance measuring precision (ISO 17123-4)
Standard
Prism tracking
Reflectorless
4.5
Tracking (LED tracker)
Peak wavelength
Typical average radiation intensity at a distance of 20 cm
(108 μs/109 Hz)
Maximum radiation intensity at a distance of 20 cm
Maximum pulse duration
Maximum pulse frequency
Beam divergence (2θ
1/2
Tracking range POA 25
Tracking range POA 20
4.6
Camera
Aperture angle (continuous focus)
Focus range
4.7
Technical data PLC 400
Weight PLC 400
Degree of protection PLC 400
Rated voltage
Capacity
Battery life
*2325080*
)
2325080
646 nm ... 674 nm
red
2
< 1 mW
0.06 ns ... 2.5 ns
3 MHz ... 102 MHz
0.1 mrad ... 5.5 mrad
2" (0.6 mgon)
4" (1.2 mgon)
2 mm + 2 ppm
(0.1 in + 2 ppm)
3 mm
(0.1 in)
2 mm + 2 ppm
(0.1 in + 2 ppm)
≤ 810 nm
3 mW/cm²
0.24 mW/cm²
108 µs
330 Hz
20°
1.5 m ... 100 m
(4 ft - 11 in ... 328 ft)
1.5 m ... 400 m
(4 ft - 11 in ... 1,312 ft)
2° ... 30°
(0.03 rad ... 0.5 rad)
≥ 5 m
(≥ 16 ft)
0.55 kg
(1.21 lb)
IP65
7.2 V
7.1 Ah
8 h