Descargar Imprimir esta página

Abicor Binzel xFUME PRO Manual De Instrucciones Original página 30

Ocultar thumbs Ver también para xFUME PRO:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
1 Identification
Table of contents
1
Identification
1.1
Marking
2
Safety
2.1
Designated use
2.2
Basic safety instructions
2.3
Electro-technical safety instructions
2.4
Welding safety instructions
2.5
Safety instructions for extraction
(according to ISO 21904)
2.6
Safety instructions regarding protective clothing
2.7
Safety instructions for use
2.8
Classification of the warnings
2.9
Emergency information
3
Product description
3.1
Technical data
3.2
Figures used
4
Putting into operation
4.1
Preparing the welding torch for cable
assembly installation
4.2
Setting up the welding torch
1
Identification
®
®
xFUME
PRO/xFUME
COMPACTfume extraction torches are MIG/MAG
welding torches for arc welding devices used for metal inert gas welding.
The devices conform to EN 60974-7 and are not considered devices that
independently fulfil functions. These operating instructions describe the
1.1
Marking
This product fulfils the requirements that apply to the market to which it has
been introduced.
2
Safety
This chapter provides you with basic safety instructions and warns you
against residual hazards which must be observed in order to operate the
product safely.
2.1
Designated use
The device described in these operating instructions may be used only for the
purpose and in the manner described in these operating instructions. The
device is used to extract welding fumes and dust that are generated when
welding. The device can be used to extract welding fumes containing CMR
substances and to extract welding fumes not containing CMR substances.
When extracting welding fumes containing CMR substances, the welding
torch must be operated in combination with a suitable W3-certified fume
2.2
Basic safety instructions
The product has been developed and manufactured in accordance with
state-of-the-art technology and the recognized safety standards and
regulations. The product can present design-related, unavoidable risks for
users, third parties, or other material property. This document provides you
with basic safety instructions and warns you against residual hazards which
must be observed in order to operate the product safely. You will find product
information and product-specific safety instructions in the separate operating
instructions and, if required, in other product-specific documentation. Non-
observance of the safety instructions may result in risks to the life or health of
personnel and result in environmental damage or material damage. The
manufacturer will accept no liability for damage caused by non-observance
of the documentation.
► Please read the documentation carefully before using the product for the
first time and comply with the instructions contained in it.
► Only operate the product in technically perfect condition in compliance
with all documentation.
► Before carrying out specific work, for example commissioning,
operation, transport and maintenance, read the documentation
carefully.
EN - 30
4.3
Connecting the cable assembly, Fig. 1
4.4
Bleeding the coolant circuit, Fig. 2
EN-30
4.5
Connecting the extraction hose
EN-30
4.6
Connecting the shielding gas and setting the gas volume
4.7
Feeding in the wire
EN-30
EN-30
5
Operation
EN-30
5.1
Handle operating elements, Fig. 3
EN-31
5.2
Welding
EN-31
5.3
Regulating the extraction volume, Fig. 3
EN-31
6
Putting out of operation
EN-31
EN-31
7
Maintenance and cleaning
EN-31
7.1
Replacing wear parts, Fig. 6
EN-31
7.2
Selecting and mounting the wire guide
7.2.1
Shortening and mounting the spiral liner, Fig. 5
EN-32
7.2.2
Mounting and shortening the PA liner, Fig. 4
EN-32
7.3
Cleaning the cable assembly
EN-32
8
Disposal
EN-32
9
Warranty
EN-33
EN-33
®
xFUME
PRO/xFUME
operated using original ABICOR BINZEL spare parts. The following figures
show the fume extraction torches in the xFUME PRO 501 version.
A corresponding marking has been affixed to the product, if required.
Non-observance of the safety instructions may result in risks to the life or
health of personnel and result in environmental damage or material damage.
extraction system. Any other use is considered improper. Unauthorised
modifications or changes to enhance the performance are not permitted.
► Do not exceed the maximum load data specified in the documentation.
Excessive loads lead to irreparable damage.
► Do not make any constructive changes to the product.
► Do not use or store the device outdoors where it is wet.
► During welding work outdoors, use suitable protection against the
weather conditions.
► Use suitable means to protect yourself and bystanders from the hazards
listed in the documentation.
► Store the documentation within easy reach of the device for reference
and enclose all documentation when passing on the product.
► Consult the documentation for the other welding components.
► When handling gas cylinders, consult the instructions from the gas
manufacturers and the corresponding local regulations, e.g. pressurised
gas regulations.
► Observe the local accident prevention regulations.
► Have commissioning as well as operating and maintenance work
carried out exclusively by qualified personnel. Qualified personnel are
persons who, based on their special training, knowledge, experience
and due to their knowledge of the relevant standards, are able to assess
the tasks assigned to them and identify possible dangers.
► Ensure the work area is well lit and keep it in good order.
► For the entire duration of servicing, maintenance and repair work, switch
off the power source, and the gas and compressed-air supply, and
disconnect the mains connection.
► For disposal, observe the local regulations, laws, provisions, standards
and guidelines.
®
xFUME
PRO/xFUME
®
COMPACT devices only. They must only be
®
COMPACT
EN-33
EN-33
EN-33
EN-33
EN-33
EN-33
EN-33
EN-33
EN-33
EN-34
EN-34
EN-34
EN-34
EN-34
EN-34
EN-35
EN-35
EN-35

Publicidad

loading

Este manual también es adecuado para:

Xfume compact