INTERFACE INPUT VOLTAGE
CURRENT ABSORPTION
MAXIMUM NUMBER OF KEYPADS THAT CAN BE LINKED
MAXIMUM NUMBER OF DIGITS PER USER CODE
MINIMUM NUMBER OF DIGITS PER USER CODE
NUMBER OF OUTPUTS AVAILABLE
NUMBER OF USER CODES THE INTERFACE CAN STORE
OUTPUT ENABLING TYPE:
OUTPUT TYPE
MAXIMUM COMMUTABLE POWER
(RESISTANCE LOAD)
RELAY ACTIVATION DELAY
MAXIMUM INTERFACE-TO-KEYPAD CABLE LENGTH
BACKLIT KEYPAD
OPERATING TEMPERATURE
DEGREE OF PROTECTION
DEGREE OF PROTECTION
PRODUCT DIMENSIONS
WEIGHT
PRODUCT DIMENSIONS
(*) Power the H85/DEC or H85/DEC2 interface with ROGER TECHNOLOGY control units. Alternatively, use safety-
compliant power supplies. The use of NON safety-compliant power supplies can cause hazards.
3
Description
The H85 code-based control system enables automated motorized systems to be controlled by entering a code. The
system comprises minimum 1 to maximum 4 H85/TDS numeric code keypads compatible with the H85/DEC interface
card, or minimum 1 to maximum 2 H85/TDS keypads compatible with the H85/DEC2 interface card.
18
H85/DEC
24 VAC-DC;
12 VDC
1 keypad 20mA
1 keypad + interface on standby 40 mA
1 keypad + interface with active relay 50 mA
4
6
3
4 for control;
1 for alarm
500
deadman's switch (enabled until key is released)
relay, voltage free contact
load in AC-DC: 60 VA/24 W
maximum current: 1 A
maximum voltage: 30VAC-DC
100 ms
100 m (two-core cable, 0.5 mm
6 white LEDs, two intensity levels
-10°C
H85/TDS : IP54
H85/DEC/BOX
H85/DEC/BOX
158x119x76
279 g
H85/TDS/I
dimensions in mm. 75x77x60 Weight: 106 g
dimensions in mm. 75x77x41 Weight: 101 g
H85/TDS/E
H85/TDS/TRIX
dimensions in mm. 75x98x58 Weight: 242 g
H85/DEC2
24 VAC-DC;
2
2 for control
2
)
+55°C
IP54
H85/DEC2/BOX
H85/DEC2/BOX
126x52x25
62 g
IPX0