CONTACT
1(0V)
2(12/24)
3(SYNC)
4(COM)
5
OUT A
6
7
OUT B
8
9
H85/DEC interface installation
Proceed with the installation as shown below (see
• Open the H85/DEC/BOX housing and wall mount it using suitable screws, not supplied.
• Make the electrical connections as shown in
10
H85/DEC2 interface installation
Proceed with the installation as shown below (see
• Open the H85/DEC2/BOX housing and wall mount it using suitable screws, not supplied.
• Make the electrical connections as shown in
11
Keypad acquisition procedure on the H85/DEC interface
H85/DEC
POWER ON
PROG
PRESS
ON
AND
HOLD
H85/TDS (nr.1)
PRESS "#"
3 times
• Power on the H85/DEC interface. The L1, L2, A, B, C, D
• Press and hold the PROG key on the H85/DEC interface for at least 10 s.
• The A, B, C, D
• The LEDs lighting up together indicates the acquisition procedure has been activated.
• Release the PROG key.
• The green LV LED and red LR LED on the H85/TDS keypad blink alternately.
• Press the # key 3 times (# # #
green LV LED lights up and the buzzer emits a long beep.
• On the H85/DEC interface, the A LED on the encoded keypad changes from blinking to steady-on mode.
• Proceed with the encoding of any other keypads (# # #). For each encoded keypad, the corresponding (B...C...D)
LEDs will light up steadily on the interface.
• For 1, 2 or 3 encoded keypads, press PROG for 2 s to end the acquisition process. The L1 LED on the interface starts
blinking. B-C-D are off.
• For 4 encoded keypads, the procedure ends automatically, after pressing the # key on keyboard 4 three times. The
L1 LED on the interface starts blinking. B-C-D are off.
WARNING! If the PROG key is released before 10 s have elapsed, the green L1 LED lights up and the acquisition
procedure is interrupted. It is advisable to power off and on again and repeat the acquisition procedure.
20
Power supply 24VAC/DC.
Connecting the keypads to the power supply.
SYNC: Terminal for connecting multiple keypads with synchronising function.
Command output A (relay contact N.A.), can be activated with the 1/A button.
Command output B (relay contact N.A.), can be activated with the 4/B button.
LIGHT UP IN SEQUENCE
10 s
H85/TDS (nr.1)
Beeeeep!
LED LV LIGHTS UP
H85/DEC2
):
.
):
.
PROG
LIGHT UP IN TOGETHER
RELEASE
LED "A" LIGHTS UP
H85/TDS (nr.1)
LED LV-LR
BLINK ALTERNATELY
PROG
L1
LED L1
x 2s
BLINKS
for 2s