Roger Technology H85/TDS Instrucciones Y Advertencias Para El Instalador página 22

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
LR LED blinks rapidly 3 times) and the code must be entered again.
• If a non-enabled function key 1/A, 4/B... is pressed, no automated operation is activated.
• If you make a mistake while entering the code, press # to exit the activation mode.
14
Identify the user code (e.g. 34741) to be deleted, and enter in sequence:
If the code is present in the memory, the red LR LED blinks and then remains steady-on.
If the two codes have been entered correctly (the same), the procedure is successful and the green LV LED lights up
for 2 s.
The buzzer remains active for the duration of the LED.
Summarizing the example with user code 34741 to be deleted. The sequence to be entered is as follows:
15
For the security of the installation, it is recommended to change the password from the factory default value 0000.
The factory default password is 0000.
Change password from 0000 to 12345, enter in sequence:
If the procedure is successful, the green LV LED lights up and the buzzer sounds for 2 s.
If the procedure is NOT successful, the red LR LED blinks rapidly 5 times and the buzzer sounds intermittently.
15.1
If the password is lost/forgotten, it can be reset to the factory default value (0000) by knowing any of the user
codes stored in H85/DEC - H85/DEC2.
N.B.: (H85/DEC2 only) To enable the password reset feature, select jumper J1 as shown in
To reset the password, if for example the user code 12345 is known, enter in sequence:
Factory password reset:
If the procedure is successful, the green LV LED on the keypad lights up for 2 s. The buzzer sounds until the LED goes
out.
If the procedure is NOT successful, the red LR LED on the keypad blinks rapidly 5 times and the buzzer sounds
intermittently.
16
All user codes can be deleted from the memory, using either the H85/TDS keypad or the H85/DEC - H85/DEC2 interface.
Memory deletion using H85/TDS keypad
Enter in sequence on the H85/TDS keypad, using the last password entered (example last password entered 87654).
If the password is correct, the green LV and red LR LEDs on the keypad blink slowly for 2 s, while the buzzer sounds
simultaneously.
Memory deletion using H85/DEC interface
To erase the memory using the H85/DEC interface, proceed as follows:
22
# # 34741 *
34741 *
# # 34741 * 34741 *
* * 0000 # (the red LR LED lights up) 12345 # 12345 #
* * 12345 # (the red LR LED lights up) 0000 # 0000 #
# # * 87654 # # *