Descargar Imprimir esta página

Hilti DX 9-ENP Manual De Instrucciones página 44

Ocultar thumbs Ver también para DX 9-ENP:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 87
Status
Worn
Always replace the pis-
ton and piston stopper
together.
Nosepiece wear criteria
Status
New condition
Worn
Have it replaced by
Hilti Service
8
Troubleshooting
8.1
Remedying malfunctions after misfiring
▶ Press the nose of the tool against the working surface and pull the trigger.
▶ A click is audible, but the cartridge does not fire.
▶ Lift the tool away from the working surface. When doing so, never point the tool toward yourself
or other persons.
▶ Advance the cartridge strip manually to the next cartridge by pushing it by hand at the cartridge
feed side or, alternatively, by pulling the cartridge strip through manually to the next cartridge at
the cartridge strip exit side.
▶ Use up the remaining cartridges on the strip. The partly-used cartridge strip must then be removed
and disposed of appropriately to prevent further use or misuse of any unfired cartridges.
8.2
Clearing the jammed tool
WARNING
Risk of explosion! Cartridges may fire (explode) if handled improperly.
▶ Do not use force to remove cartridges from the fastening tool or the magazine strip.
36
English
Illustration showing example
Illustration showing example
Annotation
The piston has made a deep im-
pression (3 mm or more) in the
piston stopper.
Annotation
Obvious signs of chipping.
2241307
*2241307*

Publicidad

loading