Appendix 1: Technical Data
Model
Nominal output
Max. operating pressure
Max. input temperature
Flue side pressure loss
Supply/return connection
Connection to pressure relief safety mechanism
Thermal safety valve sensor connection
Thermal protection water connection
Drain connection
Fuel
Flue gas mass flow
Flue gas connection
Flue gas temperature measured in the measurement
section
Flue gas temperature measured directly after the appli-
ance connection
Minimum draught
CO emission (13%O
)
2
Nox emission (13%O
)
2
CnHm emission (13%O
)
2
Particulate emission
Efficiency
Appliance weight
Heat exchanger weight
Weight of water
Weight of insulating cover
Weight of insulation (Rockwool HT600)
Total weight
Subject to change because of technical improvements
2576CBSC + heat exchanger
10.8 kW (4.4 kW water side)
3 bar
100°C
<2 Pa
G 3/4 - ISO 228
R 1/2 - EN 10226
Rp 1/2 - EN 10226
2 x Ø 15 mm
Rp 1/2 - EN 10226
Wood, maximum 50 cm
10.1 g/s
Ø 150 mm
143.5°C
340 °C
12 Pa
0.099%
54 mg/Nm³
38 mg/Nm³
40 mg/Nm³
84%
150 kg
61 kg
24 kg (24 L)
35 kg
10 kg
280 kg