6.4.2. CONTINUOUS DRAINAGE
Condensate water can be automatically flow into a bucket or drain by gravity with a water hose.
•
Set the unit in a horizontal surface and
stable position.
•
Switch off the unit before operating.
•
Gently take out the water tank from the
dehumidifier.
•
Securely and properly connect the drain hose
and make sure it is not kinked and clear of
obstruction.
•
Put back the water tank.
•
Place the outlet of hose over a drain or
bucket and ensure that water could freely
flow out of the unit.
•
Do not submerge the end of hose into
water;otherwiseit can cause "Air Lock" in the
hose.
To avoid water spillage:
•
As the negative pressure of condensate
drain pan is large, tilt the drain hose
downward toward the floor.It is appropriate
that the degree of inclination should exceed
20 degrees.
•
Straighten the hose to avoid a trap existing
in the hose.
Inner
Diameter
=9.5mm
17