Sensing range
Observe the application conditions: Adjust the distance between the sender and the
receiver according to the corresponding diagram [see
(x = sensing range, y = operating reserve).
When mounting through beam photoelectric sensors adjacent to each other, alternate the
sender (ZSO18) and receiver (ZEO18) arrangement every other pair. Also ensure that there
is sufficient distance between pairs based on the sender (ZSO18) light spot diameter. By
doing this, mutual interference can be prevented [see
Use
table 2
to check the function. If the switching output fails to behave in accordance with
table
2, check the application conditions.
Operating reserve
1.000
100
10
1
0
5
(16.4)
Figure 6: Characteristic curve, ZSE18-xxxxx3
Operating reserve
1,000
100
10
1
0
5
10
(0.2)
(0.39)
Figure 7: Characteristic curve, ZSE18-xxxxx8
3
Sensitivity setting
Sensor not possible to be set: The sensor has been adjusted by the factory to provide
maximum sensitivity and is ready for operation.
figure 6
figure
10
15
20
(32.81)
(49.21)
(65.62)
Distance in m (feet)
15
20
25
30
(0.59)
(0.79)
(0.98)
(1.18)
Distance in mm (inch)
and
see figure 7, page
32]
2].
8021945.1HW1 /2022-11-14 | SICK
Subject to change without notice