CFX100W
To defrost the cooler, proceed as follows:
➤ Take out the contents of the cooler.
➤ If necessary, place them in another cooling device to keep them cool.
➤ Switch off the device.
➤ Leave the lid open.
➤ Wipe off the defrosted water.
7.13

Replacing the AC fuse

D
DANGER! Danger of electrocution!
Disconnect the power supply and the connection cable before you
replace the device fuse.
➤ Disconnect the power supply to the device.
➤ Pull off the connection cable.
➤ Pry out the fuse insert (fig. 4 2, page 4) with a screwdriver.
➤ Replace the defective glass fuse with a new fuse of the same type and rating
(4 A, 250 V).
➤ Press the fuse insert back into the housing.
➤ Reconnect the power supply to the device.
7.14

Replacing the DC connection cable fuse

➤ Disconnect the power supply from the cooler.
➤ Remove the protective cover (fig. a 2, page 7).
➤ Replace the defective fuse (fig. a 1, page 7) with a new fuse of the same type
and rating (Automotive standard blade fuse, 10 A).
➤ Refit the protective cover.
➤ Reconnect the power supply to the cooler.
I
NOTE – Internal DC fuse
There is an additional DC fuse inside the device (Automotive standard
blade fuse, 10 A). This fuse can only be replaced by an authorised repair
centre.