Installation
14 AWG
Volts
HP
(2mm²)
110
115
1/2
(33)
438
1/2
(134)
365
230
3/4
(111)
304
1
(93)
Table 3a: Power Supply Wire (Cable) Length in Feet (m)
Single Phase, 2 Wire Cable, 60 Hz (Copper Wire Size - Service to motor)
14 AWG
Volts
HP
(2mm²)
348
1/2
(106)
203
230
1
(62)
160
1-1/2
(49)
Table 3b: Power Supply Wire (Cable) Length in Feet (m)
Single Phase, 3 Wire Cable, 60 Hz (Copper Wire Size - Service to motor)
Installation Wiring Diagrams
Risk of electric shock. Can shock,
burn or kill. Ground control box, all metal
plumbing, and motor frame with copper wire in
compliance with local codes. Use a ground wire
at least as large in gauge as the wires supplying
power to the motor.
Single Phase, 2 Wire
2-wire pumps have two power supply wires
(Black/Black) and one ground wire (Green).
Control box is not required. See Figure 1 for
correct hook-up information for 2-Wire motors.
To Line
Ground
Fused
Disconnect
Switch
Figure 1 - Single phase, 2-wire connections. This
is correct connection information for 115 and
230 volt 2-wire motors only.
12 AWG
10 AWG
8 AWG
(3.3mm²)
(5.3mm²)
(8.4mm²)
174
278
440
(53)
(85)
(134)
697
1112
1761
(213)
(339)
(537)
581
927
1468
(177)
(282)
(447)
484
772
1223
(148)
(235)
(373)
12 AWG
10 AWG
8 AWG
(3.3mm²)
(5.3mm²)
(8.4mm²)
553
883
(169)
(269)
323
515
(98)
(157)
254
406
(78)
(124)
L1
M1
L2
M2
Pressure
Switch
Black
Black
Ground
(Green)
Well
Casing
6109 1009
6 AWG
4 AWG
(13.3mm²)
(21.1mm²)
685
1092
(209)
(333)
2740
4369
(835)
(1332)
2284
3641
(696)
(1110)
1903
3034
(580)
(925)
6 AWG
4 AWG
(13.3mm²)
(21.1mm²)
1398
2175
3467
(426)
(663)
(1057)
815
1269
2023
(249)
(387)
(616)
643
1000
1594
(196)
(305)
(486)
Single Phase, 3 Wire
Permanently close all unused openings in this
and other equipment enclosures.
Disconnect power to control box before working
on or around control box, pipes, cable, pump,
or motor.
To be sure that starting relay will function and
that overload will not "nuisance trip", install
control box vertically with top side up.
Wire control box as shown in Figure 2 . A 3-wire
pump will not operate without a control box
and will burn out a 3-wire motor.
230V Line
Figure 2 - 3-wire quick disconnect box. Follow
color coding when connecting control box
(Yellow to Y, Red to R, Black to B).
3 AWG
2 AWG
(26.7mm²)
(33.6mm²)
1373
1734
(419)
(529)
5492
6936
(1674)
(2114)
4577
5780
(1395)
(1762)
3814
4817
(1163)
(1468)
3 AWG
2 AWG
(26.7mm²)
(33.6mm²)
4359
5505
(1329)
(1678)
2543
3211
(775)
(979)
2004
2531
(611)
(772)
115V or
Ground
Fused
disconnect
switch
L1 M1
L2
M2
Red
Yellow
Black
Well
casing
5
1 AWG
0 AWG
(42.4mm²)
(53.5mm²)
2184
2757
(666)
(840)
8738
11029
(2663)
(3362)
7281
9191
(2219)
(2801)
6068
7659
(1849)
(2335)
1 AWG
0 AWG
(42.4mm²)
(53.5mm²)
6935
8753
(2114)
(2668)
4045
5106
(1233)
(1556)
3189
4025
(972)
(1227)
Sub.
Motor
Control
L1L2R Y B
Pressure
switch
Ground
699 0993