Descargar Imprimir esta página

geberit ESG 3 Manual De Instrucciones página 46

Ocultar thumbs Ver también para ESG 3:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 131
EN
To cancel the welding procedure, press the start button.
<Welding procedure> LED display
the coupling connection plugs. <Malfunction> LED display
seconds. <Malfunction> LED display
Repeat the welding procedure with the cooled Geberit
electrofusion coupling or the cooled Geberit electrofusion
tape for anchor point.
4
Welding is completed after approx. 80 seconds (in the case
of electrofusion couplings with integrated thermal fuse,
approx. 7 minutes).
✓ <Welding procedure> LED display
Result
✓ Welding has been performed correctly.
46
flashes. Press the start button and hold for three
the <Welding complete> LED display
(see figure D,
i
, page 394).
goes out. Remove
goes out.
goes out and
lights up
9962820747 © 01-2023
966.473.00.0(03)

Publicidad

loading