Technical data
Technical data
Display
Rated voltage range
Rotating field display
Indication
Frequency range
Duty cycle
Nominal In current
Phase test pole
Continuity testing
Operating temperature
Protection class
Overvoltage category
Test standard
Voltage supply
18
11 LEDs for voltage (12, 24, 50, 120, 230, 400, 690 and 1000 V), polarity ( + ~ - ),
continuity (Rx) and phase/rotating field (R / L), ELV
6...1000 V AC
6...1500 V DC
Yes
0.85 Un
40 ... 400 Hz
30 s on / 240 s off
< 3.5 mA
> 100 V AC
0...500 k
-5 to +40 °C, at > 85% RH
IP 64
CAT IV 1000 V
EN 61243-3:2014
2x 1.5 V Type AAA micro
®
Testboy
Profi III DUO