Troubleshooting
When operating with different protocols you may have
problems in each mode at the same time.
– We recommend reducing the number of protocols.
Deactivate protocols in the locomotive decoder that are
not needed and also deactivate if possible protocols in
the central controller that are not needed.
The locomotive jerks and falters
– Check the CV setting for motor variations, change if
necessary, or carry out a reset to the factory settings.
The locomotive does not run in analog.
– The automatic analog recognition is deactivated and
must be activated again (see CV table).
The locomotive (decoder) does not react.
– Check the wiring and the solder joints, redo if necessary.
Check the connector for the decoder to make sure it has
permanent contact and check the way it was installed.
34