19 Spare Parts and Accessories
– Energy content in Wh: see rating label
– Weight in kg: See rating label
18.4
STIHL AL 101 Charger
– Rated voltage: See rating plate
– Frequency: see rating plate
– Rated power: see rating plate
– Charging current: See rating plate
For charging times, see www.stihl.com/charging-
times.
18.5
Extension Cords
If an extension cord is used, the cross sectional
area of its conductors must meet the following
minimum requirements – depending on the line
voltage and length of the extension cord:
If rated voltage on the rating label is 220V to
240V:
– Cord length up to 20 m: AWG 15 / 1.5 mm²
– Cord length 20 m up to 50 m: AWG 13 /
2.5 mm²
If rated voltage on the rating label is 100V to
127V:
– Cord length up to 10 m: AWG 14 / 2.0 mm²
– Cord length 10 m up to 30 m: AWG 12 /
3.5 mm²
18.6
Temperature limits
WARNING
■ The battery is not protected against all ambi‐
ent conditions. If the battery is exposed to cer‐
tain environmental conditions, it may catch fire
or explode. This may result in serious injury to
people and damage to property.
► Do not charge the battery below -20°C or
above +50°C.
► Do not use the hedge trimmer, battery or
charger below -20°C or above +50°C.
► Do not store the hedge trimmer, battery or
charger below -20°C or above +70°C.
18.7
Recommended temperature
ranges
For optimum performance of the hedge trimmer,
battery and charger, observe the following tem‐
perature ranges:
– Charging: 5°C to 40°C
– Use: - 10 °C to + 40 °C
– Storage: - 20 °C to + 50 °C
If the battery is charged, used or stored outside
the recommended temperature ranges, perform‐
ance may be reduced.
0458-019-9801-A
If the battery is wet or moist, allow the battery to
dry for at least 48 h between 15°C and 50°C and
with less than 70% humidity. Higher humidity
may extend the drying time.
18.8
Sound Values and Vibration
Values
The K-value for the sound pressure level is
2 dB(A). The K-value for the sound power level is
2 dB(A). K-value for vibration level is 2 m/s².
STIHL recommends wearing ear defenders.
– Sound pressure level L
to EN 62841-4-2: 77 dB(A).
– Sound power level L
EN 62841-4-2: 85 dB(A).
– Vibration level a
measured as specified in
hv
EN 62841-4-2
– Control handle: 1.0 m/s². The K value for
the vibration level is 2 m/s².
– Loop handle: 1.5 m/s².
The vibration levels indicated were measured
according to a standardized test method and can
be used as a basis for comparing electric power
tools. The vibration levels actually occurring may
vary from the values indicated, depending on the
type of application. The vibration levels indicated
can be used for an initial estimate of the vibration
stress. The actual vibration stress has to be esti‐
mated. The times can be taken into account in
the estimate when the electric power tool is
switched off and also when it is switched on but
running without any load.
For information on compliance with Employers'
Vibration Directive 2002/44/EC see
www.stihl.com/vib.
18.9
REACH
REACH is an EC regulation and stands for the
Registration, Evaluation, Authorisation and
Restriction of Chemical substances.
For information on compliance with the REACH
regulation see www.stihl.com/reach.
19 Spare Parts and Accesso‐
ries
19.1
Spare parts and accessories
These symbols indicate original STIHL
spare parts and original STIHL acces‐
sories.
STIHL recommends the use of original STIHL
spare parts and accessories.
English
measured according
p