2.AIR CLEANER SERVICE
A dirty air cleaner will restrict air flow to the carburetor. To prevent
carburetor malfunction, service the air cleaner regularly. Service more
frequently when operating the generator in extremely dusty areas.
Do not use gasoline or low flash point solvents for cleaning. They are
flammable and explosive under certain conditions.
CAUTION:
Never run the engine without the air cleaner element. Rapid engine
wear will result.
1.Unsnap the two air cleaner cover
clips, remove the air cleaner cover,
and remove the air cleaner element.
2.Clean in warm soapy water, rinse and allow to dry to thoroughly. Or
clean in high flash point solvent and allow to dry. Dip the element in
clean engine oil and squeeze out all the excess. The engine will
smoke during initial startup if too much oil is left in the foam.
Clean
3.Reinstall the air cleaner element and the cover.
• properly
hooked
38
Squeeze and dry
Do not twist.
• improperly
hooked
AIR CLEANER
COVER
AIR CLEANER
AIR CLEANER
COVER
ELEMENT
Dip in oil
Squeeze
Do not twist.
AIR CLEANER
ELEMENT