Installation Instructions: Introduction and Overview
The Cassette indoor unit ships separately from the
accessories. Accessories include the cassette panel, remote
control, and wired controller.
The Cassette unit will install between standard dropped ceiling
grids. It is mounted using threaded rods that fit into brackets that
are located at all four corners of the cassette assembly.
The Cassette unit receives 230 volt line voltage from a
connection at the outdoor condensing unit. There is no
requirement for independent line voltage connections.
The cassette unit has a built in condensate pump and
associated float switch that manages the operation of the
condensate pump. A flexible hose is included with the
Cassette unit. This hose connects the cassette condensate
drain outlet to the buildings condensate drain system.
The motorized louver is controlled via the remote control.
The louver has indicator lights that communicate function and
diagnostic information to the user and service technician.
Factory provided insulating tape is included with the cassette
unit. This tape should be placed over the refrigerant piping
connections at the indoor unit to prevent sweating.
Indoor
Rated Cooling Capacity Btu/hr
Rated Heating Capacity Btu/hr
Voltage, Cycle, Phase V/Hz/-
Fan Speed Stages
CFM
Motor Speed (Turbo/High/Med/Low/
"Indoor Sound Level dB
Grill Model
Chassis Dimension: Height in (mm)
Chassis Dimension: Width in (mm)
Chassis Dimension: Depth in (mm)
Grill Dimension: Height in (mm)
Grill Dimension: Width in (mm)
Grill Dimension: Depth in (mm)
Weight (Ship/Net)- lbs (kg)
Connections
Liquid O.D. in
Suction O.D. in
Drainpipe Size O.D. in
Internal Condensate Pump
Max. Drain-Lift height in(mm)
31-5000516 Rev. 3
Cassette Product Information
Large Cassette (3'X3') Unit Specifications
USYL24UCDDA
24,000
26,000
208/230/60/1
5+Auto
824/752/587/482
582/540/430/360
46/44/39/37
"PB-950KD (Haier)
PB-950NB (GE)"
9 5/8 (246)
33 1/8(840)
33 1/8(840)
2 (50)
37 3/8 (950)
37 3/8 (950)
89.5/61.9(40.6/28.1)
Flare
3/8
5/8
1 1/4
Standard
39 3/8 (1000)
Remote. See Owner's manual for
more information
Wired controller (remote
control and cover panel
not included)
USYL30UCDDA
USYL36UCDDA
30,000
36,000
31,000
37,000
208/230/60/1
208/230/60/1
5+Auto
5+Auto
967/871/780/710
967/871/780/710
730/650/550/450
730/650/550/450
51/50/48/46
51/50/48/46
"PB-950KD (Haier)
"PB-950KD (Haier)
PB-950NB (GE)"
PB-950NB (GE)"
11 3/8 (288)
11 3/8 (288)
33 1/8(840)
33 1/8(840)
33 1/8(840)
33 1/8(840)
2 (50)
2 (50)
37 3/8 (950)
37 3/8 (950)
37 3/8 (950)
37 3/8 (950)
91.7/66.1 (41.6/30)
91.7/66.1 (41.6/30)
Flare
Flare
3/8
3/8
3/4
3/4
1 1/4
1 1/4
Standard
Standard
39 3/8 (1000)
39 3/8 (1000)
Outside Air
Mounting Hangers
USYL42UCDDA
USYL48UCDDA
42,000
47,000
44,000
47,000
208/230/60/1
208/230/60/1
5+Auto
5+Auto
1236/967/830/740
1236/967/830/740
800/730/600/500
800/730/600/500
54/51/48/46
54/51/48/46
"PB-950KD (Haier)
"PB-950KD (Haier)
PB-950NB (GE)"
PB-950NB (GE)"
11 3/8 (288)
11 3/8 (288)
33 1/8(840)
33 1/8(840)
33 1/8(840)
33 1/8(840)
2 (50)
2 (50)
37 3/8 (950)
37 3/8 (950)
37 3/8 (950)
37 3/8 (950)
91.7/66.1 (41.6/30)
91.7/66.1 (41.6/30)
Flare
Flare
3/8
3/8
3/4
3/4
1 1/4
1 1/4
Standard
Standard
39 3/8 (1000)
39 3/8 (1000)
5