1. Fill water into solution tank (3) from the inlet (20) through pipe or bucket
2. Do not fill the solution tank completely, leave a few centimeters from the edge.
3. The water temperature must not exceed 40
1
Unscrew the drain cap (22) on the bottom of solution tank. The solution/water will flow
freely into a bucket or floor drain.
2
Rinse the solution tank with clean water after every use. This will help prevent chemical
build up and clogging of the solution lines
3
Screw up the drain cap (22).
1
Turn the latch (17) off the recovery tank, take off the recovery tank from machine by
grasping two grooves of tank. Open the lid (1) and overturn the recovery tank to
drain the dirty water into a container, or unscrew the drain cap (22) to let water pipe
out to a bucket.
2
Clean and Rinse the recovery tank with clean water after every use.
3
Re-place the recovery tank on the machine and turn the latch (17) to lock the tank..
1
Set the handle to a comfortable height by pressing level (25).
2
Lower the squeegee (33) onto the floor by pulling down the lift mechanism (26).
.