ENGLISH
[3] Storage Bin Interior Cleaning/Sanitisation
(Weekly)
) Open the Storage Bin Door, and remove all ice.
2) Remove the Thumbscrews securing the Baffle.
3) Remove the Baffle from the Bin.
4) Wash the Bin liner and Baffle with a neutral non-
abrasive cleaner. Rinse thoroughly.
5) Either mix 5 litres of water with 8 ml of 5.25%
sodium hypochlorite solution in a suitable
container, or t he r ec omm en de d Ho sh izaki
sanitiser as directed.
6) Soak a clean sponge or cloth with the solution and
wipe the Bin liner surfaces and Baffle.
7) Refit the Baffle and Thumbscrews. Wipe the
surface of the Bin Door and Thumbscrews with
the solution. Close the Bin Door.
8) The remaining solution can be used to sanitise
utensils.
Note: Do not wipe dry or rinse after sanitising, but
allow to air dry.
[4] Storage Bin Door
Clean the Storage Bin Door at least once a week,
using a neutral non-abrasive cleaner. Rinse
thoroughly after cleaning and sanitise as required.
[5] Air Filter
Plastic mesh Air Filters remove dirt or dust from the
air, and keep the Condenser from getting clogged. If
the Filters get clogged, the icemaker's performance
will be reduced. Remove and clean the Air Filters at
least twice per month:
) Slide the Air Filter off the Louver.
2) Clean the Air Filter by using a vacuum cleaner.
When severely clogged, use warm water and a
neutral cleaner to wash the Air Filter.
3) Rinse and dry the Air Filter thoroughly, and place
it in position.
Air Filter
2. SERVICE CALL
WARNING
Do not damage the refrigerant circuit. In the
case of accidental damage to the refrigeration
system causing refrigerant leak, do not create
a source of ignition in the area. Do not operate
electrical switches or plugs in the area, do not
use naked flame. Immediately ventilate the
area by opening doors and/or windows, and
call service engineer.
[1] Error Code Indication
If the error code "E" is indicated on the display,
before calling for service, check the following.
Code
E0
Possibility of water leaks. Press Reset Button. If error
code appears again, call for service.
E1
Low ice production. Press Reset Button. If error code
appears again, call for service.
E2
Water supply circuit failure. Press Reset Button. If error
code appears again, call for service.
E3
Gear Motor failure. Turn OFF Operation Switch, and turn
it ON again after 0 minutes. If error code appears again,
call for service.
E4
Abnormal high side pressure. Clean Air Filter. Check that
icemaker is properly installed according to Installation
Manual. Press Reset Button. If error code appears again,
call for service.
E5
Electric circuit failure. Press Reset Button. If error code
appears again, call for service.
E8
Compressor could be overheated. Check that icemaker
is properly installed according to Installation Manual.
Turn OFF Operation Switch, and turn it ON again after 0
minutes. If error code appears again, call for service.
Eb
Electric circuit failure. Press Reset Button. If error code
appears again, call for service. (Ice production continues.)
EC
Electric circuit failure. Press Reset Button. If error code
appears again, call for service.
Ed
Gear Motor could be overloaded. Press Reset Button. If
error code appears again, call for service.
EE
Gear Motor is in abnormal rotation. Press Reset Button. If
error code appears again, call for service.
EF
Supply voltage is too low. Check that voltage is in required
range and icemaker is not sharing a single receptacle
with other appliances. Press Reset Button. If error code
appears again, call for service.
4
Louver
Fig. 2
Remedy