Operating Manual SATAjet 1500 B RP/HVLP
accurate method):
rule of thumb: pressure at the pressure reducer must be set 0.6
bar higher than the recommended spray gun inlet pressure per
every 10 m of air hose (inner width 9 mm).
7.2. Adjustment of the Material Flow
und [4-4] - material flow control fully opened
With the material flow control fully opened, the wear of the fluid tip and
paint needle is reduced to a minimum. Please select the correct nozzle
size depending on the material to be applied and the required applica-
tion speed.
7.3. Adjustment of the Spray Fan Pattern
• Adjust flat fan (factory setting) [5-1].
• Adjust round fan [5-2].
7.4. Painting
Fully pull trigger for painting [6-1]. Operate spray gun according to [6-2].
Maintain spray distance as described in chapter 2.
8.
Cleaning the Spray Gun
• Prior to cleaning, please disconnect the spray gun from the compressed air
circuit!
• Risk of injury due to unexpected leakage of compressed air or mate-
rial!
• Empty spray gun and gravity flow cup completely, dispose of paint
material appropriately!
• Disassemble and install components very carefully! Exclusively use
included special tools!
• Use neutral cleaning solution (pH value 6 to 8)!*
• Do not use acids, lyes, pickling agents, unsuitable re-
claimed materials or other aggresive cleaning media, such
as Toluol, for example!*
• Do not soak spray gun in cleaning solution!*
Information!
Danger! Notice!
[4-1], [4-2], [4-3]
US
63