Operating Manual SATAjet 1500 B RP/HVLP
US
the air micrometer and spring with SATA high performance grease (Art.
No. 48173), insert them together with the air piston and thighten the
locking screw [10-1]. Adjust material flow according to chapter 7.2 after
installation.
• Check if the locking screw has been firmly tightened! The air microm-
eter could shoot out from the spray gun uncontrolled!
9.5. Replacing the Sealing (air side)
• Disconnect the spray gun from the compressed air circuit!
Steps: [9-1], [9-2], [10-1], [10-2], [10-3], [10-4] and [10-5]
Replacing the self-tensioning sealing [10-5] is required when air leaks
from under the trigger.
1. After disassembly, please check air piston rod [10-4] and clean it, if
required. If damaged (e.g. if scratched or bent), replace it and grease
with SATA high performance spray gun grease (Art. No. 48173) and
insert. Please observe correct order of installation!
2. Lubricate air micrometer (air flow control) and spring as well, insert
together with air piston and tighten the locking screw.
After installation, please adjust material flow according to chapter 7.2.
• Check if the locking screw has been firmly tightened! The air microm-
eter could shoot out from the spray gun uncontrolled!
9.6. Replacing the Spindle of Round/Flat Spray
Control
It needs to be replaced when air leaks from the control knob or when flat/
round control does not work. After disassembly, apply some sealant on
thread of the spindle, e.g. Loctite 242 [11-4].
66
Danger!
Danger!
Danger!
Steps: [11-1], [11-2], [11-3], [11-4]