INSTALLATION PROCEDURE - Tank
[ 0.8 gallon (3L) Tank Type ]
Using the bracket to anchor the tank on the floor.
1. Anchor the tank and the brackets with the
decorative screws that should be tightened by
hand.
2. Install the tank on the floor with the screw.
Note
If the floor is made of concrete, embed the curl
plugs first.
[ 0.26 gallon (1L) Tank Type (special order)]
1. Anchor the bracket with the attached
round-head screw.
2. Pass the constricted part of the tank
between the bracket and insert it the full
depth.
3. Insert the tank in the slit on the bottom
surface of the bracket and pass it through
the two holes.
4. Attaching the bundling band.
* The bundling band serves to prevent the
tank from falling off if the tank collides
with something.
If the tank is installed behind a wall, etc., it
is not necessary to attach the bundling
band.
Tank
2. Screw
Bracket
1. Decorative screw
Wall surface
Two round-head
Bracket
screws
(Φ 5.1 mm x 32 mm)
Constricted part
Bracket
2. Insert it
the full depth.
3.
Hole
Slit on the bottom of
the bracket
4. Bundling band
8
INSTALLATION PROCEDURE - Connecting Hoses and Cords
Hose Connections
1. Cut the hoses to an appropriate length that
reaches to the connected part.
(Between the spouts and the controller)
(Between the controller and the tank)
Caution
Using a cutter, etc., cut the hoses so that the
cut surface becomes vertical.
2. Insert the hose fully into the controller and
put the hose clamp on the projection of the
joint to anchor the hose securely.
Hose
Hose clamp
Projection of joint
Caution
Connect the hoses and sensors in the
predetermined pairs.
When inserting the hoses, pay attention not
to apply strong force to the joint of the tank.
Pay attention not to bend the hoses.
[ Tank side ]
[ Controller side ]
0.8 gallon (3L) Tank 0.26 gallon (1L) Tank
(special order)
Liquid soap hose (clear)
Connect it to the tank.
Liquid soap hose (clear)
Connect it to the spout.
Air hose (blue)
Connect it to the spout.
Connect the hoses
and sensors in the
predetermined pairs.
* Connect the single type to
only.
(The sensor does not work in any other
position.)
* Connect the double type to
and
(
does not work.)
9
.