GAS SPECIFICATION
GAS TYPE AND PRESSURE
G30 29 mbar
G20 20 mbar
ELECTRICAL CONNECTION:
This appliance must be earthed.
This appliance is design ed to be connected to a 220-240 V, 50-60 Hz electricity supply.
The wires in the mains lead are coloured in accordance with the following code:
Green/yellow → Earth
-
Blue → Neutral
-
Brown → Live
-
The wire which is coloured green and yellow must be connected to the terminal which is
marked with the letter E or by the earth symbol.
WIRING DIAGRAM
When the power cord is damaged it must be replaced by the manufacturer to produce,
customer service agent or similarly qualified personnel.
GAS ADJUSTMENT:
Take precautions on the operations and adjustments to be carried out when converting from
one gas to another.
All work must be carried out by a qualified technician.
Before you begin, turn off the gas and electricity supply to the appliance.
HEAT INPUT AND ORIFICE SIZE MARKED (MM)
Wok burner
Rapid burner
3,3kW
(241g/h)
0,93
1,28
Semi-rapid
/
1,75 kW
(127 g/h)
/
0,66
/
1,00
Auxiliary - rapid
1,0 kW
(73 g/h)
0,50
0,78