1. Change the injector of the burners
Remove the pan support, burner lid and flame spreader.
Unscrew the injector using a 7mm box spanner and replace it with
the stipulated injector for new gas supply. Carefully reassemble all
the components.
After injectors are replaced, it is advisable to strongly tighten the
injector in place.
2. Adjustment of mínimum level of the flame
1. Turn the taps down to mínimum.
2. Remove the knob from the tap and place a small bladed screwdriver in the
centre of the tap shaft.
3. The correct adjustment is obtained when the flame has a length of about 3-4
mm.
- For butane / propane gas, the adjusting screw must be tightly screwed in.
- Refit the control knob.
Make sure that the flame does not go out by quickly turning from maximum flow to
minimum flow. If it does then remove the control knob and make further
adjustments to the gas flow, testing it again once the adjustment has been
made.
4. Repeat this process for each one of the gas taps.
Do not dismantle the tap shafe: in the event of malfunction, change the whole tap.
Before placing the burners back on the top place, make sure that the injector is not blocked.
A full operational test and a test for possible leakages must be carried out after gas
conversion (such as soap water or gas detector).
After completing conversion, a qualified technician or installer has to mark "V" on the right
gas category to match with the setting in rating plate. Remove the previous "V" mark.
Injector
Control handle
Tap
Sealing ring
Adjustment screw