Segment test / firmware version:
The segment test is carried out automatically every 5
minutes. If required, the segment test can be called
up via the menu level using a smartphone with
activated NFC function . The firmware version can
also be read out via NFC interface if required and is
displayed in the NFC tag.
Consumption value:
DN15 to DN50, 9-digit, with 3 digits after the
■
decimal place.
The number of decimal places may vary depend-
■
ing on the unit, in the case of m³, 3 decimal places
are shown.
Leading zeros (pre-decimal positions) of the
■
consumption display are not displayed at the start
(display 0.000 or 0.00). These are increased once
the respective volume has been reached.
In the event of an overrun, all leading zeros are
■
displayed in the consumption display
(display 000000.000).
The actual consumption is fully recorded in the
■
internal memory following an overrun and can be
retrieved via the NFC interface.
Unit of consumption display: m³
■
(for the Gal and CF display units, as well as the
x10 or x100 factors, this involves factory-preset
programmable country-specific units / factors)
Attention!
If the upper measuring limit is exceeded, the flow
rate display is deactivated and FOR = Flow Out of
Range is displayed.
During the overrun period, no consumption progress
is registered. The last overload message is stored in
the error memory as undersized detection.
Data logger
The unit has an extensive data logger.
The data logger is read out using the Android app
ZENNER Device Manager Basic.
The file format can be selected as PDF or CSV.
ZENNER International GmbH & Co. KG
Heinrich-Barth-Straße 29 | 66115 Saarbrücken | Germany
Phone
+49 681 99 676-30
Fax
+49 681 99 676-3100
E-Mail
info@zenner.com
Internet
www.zenner.com
Disposal
This device contains a non-removable and
nonrechargeable lithium battery. Batteries contain
substances, which could harm the environment
and might endanger human health if not disposed
of properly. To reduce the disposal quantity so
as unavoidable pollutants from electrical and
electronic equipment in waste, old equipment
should be reused prior or materials recycled or
reused as another form.This is only possible if
old equipment, batteries, other accessories and
packaging of the products are returned to the
manufacturer or handed in at recycling centres.
Our business processes generally provide that
we or the specialist companies we use take old
devices including batteries, other accessories and
packaging material back with us after they have
been replaced or at the end of their useful life and
dispose of them properly.
Insofar as no other contractual arrangement has
been made in this respect, your local or municipal
authority or the local waste disposal company can
give you information relating the collection points
for your used equipments. ZENNER will always
ensure correct disposal.
Caution!
Do not dispose of the devices with domestic
waste. In this way, you will help to protect natural
resources and to promote the sustainable reuse of
material resources.
For any question, please contac info@zenner.com
The declaration of conformity and the newest
information on this product can be called up from
www.zenner.com.
12