Electrical Safety - WIKA GLS-1000 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

9. Specifications
Overview of floats
Form
Outer
EN
∅ D
Cylinder 44 mm
[1.7 in]
Cylinder 30 mm
[1.2 in]
Cylinder 25 mm
[1.0 in]
Sphere
52 mm
[2.0 in]

Electrical safety

Short-circuit resistance
Reverse polarity protection
Insulation voltage
Overvoltage protection
For further specifications see WIKA data sheet LM 50.10 and the order
documentation.
18
Height
Operating
H
pressure
52 mm
≤ 16 bar
[2.0 in]
[≤ 232 psi]
36 mm
≤ 10 bar
[1.4 in]
[≤ 145 psi]
20 mm
≤ 16 bar
[0.8 in]
[≤ 232 psi]
52 mm
≤ 40 bar
[2.0 in]
[≤ 580 psi]
WIKA operating instructions model GLS-1000
Medium
Density
tempera-
ture
≤ 110 °C
≥ 750 kg/m³
[≤ 230 °F]
[46.8 lbs/ft³]
≤ 110 °C
≥ 850 kg/m³
[≤ 230 °F]
[53.1 lbs/ft³]
≤ 80 °C
≥ 750 kg/m³
[≤ 176 °F]
[46.8 lbs/ft³]
≤ 110 °C
≥ 750 kg/m³
[≤ 230 °F]
[46.8 lbs/ft³]
SP1 / SP2 / SP3 / SP4 vs. U-
U+ vs. U-
DC 500 V
DC 40 V
Material
316 Ti
316 Ti
Buna /
NBR
316 Ti

Publicidad