9. Specifications
Models DPGS43.100, DPGS43.160
Pressure limitation
- Steady
EN
- Fluctuating
- Overpressure safety minimum 10 x full scale value, max. 25 bar
Temperature effect
For further specifications see data sheet PV 27.05
Models DPGS43HP.100, DPGS43HP.160
Pressure limitation
- Steady
- Fluctuating
- Overpressure safety 40, 100, 250 or 400 bar
Temperature effect
For further specifications see data sheet PV 27.13
Model 232.35
Pressure limitation
- Steady
- Fluctuating
- Short time
Temperature effect
For further specifications see data sheet PM 02.11
Models 432.56, 432.36
Pressure limitation
- Steady
- Fluctuating
- Overpressure safety 40, 100 or 400 bar
Temperature effect
For further specifications see data sheet PV 24.07
26
Operating instructions pressure gauges with switch contact models 821, 851 or 830 E
Full scale value
0.9 x full scale value
When the temperature of the measuring system deviates from the
reference temperature (+20 °C): max. ±0.5 %/10 K of full scale value
Full scale value
0.9 x full scale value
When the temperature of the measuring system deviates from the
reference temperature (+20 °C): max. ±0.5 %/10 K of full scale value
3/4 x full scale value
2/3 x full scale value
Full scale value
When the temperature of the measuring system deviates from the
reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value
Full scale value
0.9 x full scale value
When the temperature of the measuring system deviates from the
reference temperature (+20 °C): max. ±0.8 %/10 K of full scale value