9. Specifications
Models 532.52, 532.53 and 532.54
Pressure limitation
- Steady
- Fluctuating
- Overpressure safety Minimum 1 bar absolute pressure (atmospheric pressure), in ad-
Temperature effect
For further specifications see data sheet PM 05.02
Model 632.51
Pressure limitation
- Steady
- Fluctuating
- Overpressure safety 50 x full scale value
Temperature effect
For further specifications see data sheet PM 06.06
Model 736.51
Pressure limitation
- Steady
- Fluctuating
- Overpressure safety ⊕ side: 200 mbar
For further specifications see data sheet PM 07.08
Operating instructions pressure gauges with switch contact models 821, 851 or 830 E
Full scale value
0.9 x full scale value
dition 10 x full scale value, max. 25 bar absolute pressure
When the temperature of the measuring system deviates from the
reference temperature (+20 °C): max. ±0.8 %/10 K of full scale value
Full scale value
0.9 x full scale value
When the temperature of the measuring system deviates from the
reference temperature (+20 °C): max. ±0.6 %/10 K of full scale value
Full scale value
0.9 x full scale value