4.1.2.1.2- Control
The equipment allows you to select from 2 different modes of control:
Manual: The equipment produces chlorine continuously, depending on the
% of production selected. If you have a fitted FREE CHLORINE PROBE or ORP
PROBE, it will ignore its value and chlorination will not stop even though the set
value has been exceeded. When selecting this mode, the equipment will ask if
you want to display the value of the PPM/mV on the main screen.
Select this mode if you do not have a Kit Advanced or PRO/2, by
adjusting production and hours of filtering depending on the nature of your
swimming pool, its volume number of bathers and season of the year.
Automatic
Select this mode only if you have an ORP or Amperometric probe kit. If
you do not have a probe, the equipment will act at random and end up by
stopping and showing an error.
This mode enables you to automatically adjust the level of chlorine in your
swimming pool. Based on the adjusted set value in the "chlorine" menu, the
equipment will stop when it reaches this value, and start-up again automatically
when there is a need for chlorine.
4.1.2.1.3- Cleaning
The equipment includes an automatic cleaning system, based on reversing
polarity in the electrolysis cell. These cleaning cycles are performed regularly.
The time between cleaning (in hours) can be adjusted depending on the water
hardness of your swimming pool.
It is possible to select cleaning intervals from 1 to 8 hours.
58 / 66
Manual PRO200-IP65 v1.0